Vulcan-Hart ML-136059 Electric Steamer User Manual


 
MODEL C24EA - CONTROL BOARD
F35453 (July 2008)Page 39 of 68
Water Level at LLCO Probe
LLCO LED is on (water level control) (LED is on until water drops below LLCO probe).
All contactors energized (steam generator begins heating).
Water fill of the steam generator changes to slow fill rate.
LED
STATUS
COMPONENT DESCRIPTION
ON OFF
1 X Same as Starting Conditions
2X
Limiting contactor (1CON) energized. Water level is satisfied (LLCO probe).
Limiting contactor (1CON) will remain
energized with the water level satisfied.
3X
Regulating contactor 1 (2CON) energized. Pressure switch (1PAS) closed; Heating
elements powered.
4X
Regulating contactor 2 (3CON) energized. Pressure switch (1PAS) closed; Heating
elements powered.
12 X Same as Starting Conditions
13 X Same as Delime Switch On
14 X Same as Delime Switch On
15 X Same as Delime Switch On
17 X Same as Delime Switch On
All other LED's are off.
Water Level at Low level (L) Probe
Water level control no changes.
Control Board no changes.
Water Level at High Level (H) Probe
HL LED off (water level control).
Water fill of steam generator ends (slow fill valve de-energized).
LED
STATUS
COMPONENT DESCRIPTION
ON OFF
1 X Same as Starting Conditions
2 X Same as Water Level at LLCO Probe
3 X Same as Water Level at LLCO Probe Heating elements remain powered.
4 X Same as Water Level at LLCO Probe Heating elements remain powered.
12 X
Vacuum relief solenoid (2SOL) de-
energized.
Pressure switch opens (2PAS). Allows
steam generator to fully pressurize.
13 X Same as Delime Switch On
14 X Same as Delime Switch On
15 X Same as Delime Switch On
17 X Same as Delime Switch On
All other LED's are off.