Vulcan-Hart ML-136059 Electric Steamer User Manual


 
MODEL C24EA - HEATING ELEMENTS AND CONTACTORS
F35453 (July 2008)Page 17 of 68
3. If unable to check current draw, a resistance check may indicate a malfunctioning element.
A. Turn power switch off and disconnect power to machine.
B. Disconnect heating element lead wires and check the individual element resistance using a VOM.
C. If resistance readings are not correct, replace heating element.
4. Check steamer for proper operation.
VOLTAGE
KW PER
ELEMENT
CURRENT PER
ELEMENT
RESISTANCE PER
ELEMENT (OHMS)
208
1
8.0 12.8 16.2
240
1
10.5 14.8 16.2
480
2
8.0 9.6 28.8
208
1
8.0 12.8 16.2
240
1
10.5 14.8 16.2
480
2
8.0 9.6 28.8
1
Dual voltage elements.
2
480V elements are connected in Wye configuration for 277V across each element.
NOTE: Values in table are nominal. Tolerance is ±10 %.