Vulcan-Hart ML-136059 Electric Steamer User Manual


 
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
F35453 (July 2008)Page 25 of 68
NOTE: When installing, align the flat on delime valve
stem and the locking pins on delime valve to the
motorized control assembly.
NOTE: The two electrical plugs on the motorized
control assembly are identical. If the electrical wiring
is not connected correctly, the motorized drain valve
will not function.
4. Note location of electrical wiring then disconnect
from motorized control assembly.
5. Disconnect drain and drain cooling hoses from
pipe tee located below drain valve.
NOTE: Use new band clamps when connecting
hoses. See TOOLS.
6. Remove drain valve from steam generator.
7. Remove pipe tee and nipple plumbing assembly
from drain valve.
8. Reassemble parts removed in reverse order.
Apply pipe thread sealant to pipe threads before
installation.
NOTE: If motorized drain valve is in the open
position when power is applied to the steamer with
the power switch on, drain valve will not close and fill
water will flow through the steam generator into the
drain.
9. Verify power switch is in the off position and the
motorized drain valve is closed before applying
power to steamer.
NOTE: When power is applied and power switch is
off steamer will enter a drain cycle.
10. Check steamer for proper operation and leaks
around drain valve.