Blodgett BX-14G Oven User Manual


 
Installation
12
Deliming System Connection (BCXĆ14 units only)
1. Push deliming tube onto barbed fitting on
oven back.
Figure 6
2. Cut deliming tube to length using the bottom
of the deliming fluid reservoir in its mounted
position as a guide. Install the jug weight on
the deliming fluid reservoir end of the deliming
tube.
Figure 7
3. Insert the end of the deliming tube with the jug
weight into the deliming solution reservoir.
Figure 8
4. Prime the pump by placing oven in COOL
DOWN mode with the oven on and press and
hold the STEAM ON DEMAND button. Watch
for deliming solution to flow through tube. This
will tell you the pump is working correctly. ReĆ
lease the STEAM ON DEMAND button once
deliming solution has reached the oven back.
NOTE: If needed use supplied hose retainers and
self drilling screws to route the deliming
tube away from hot exhaust ports.