Blodgett BX-14G Oven User Manual


 
Maintenance
31
Deliming (BCXĆ14 units only)
DELIMING INTERVAL SETTING
Refer to Figure 22 to determine the correct delimĆ
ing interval for your appliance. Find your location
and the corresponding potentiometer setting.
These values are general and are guidelines only.
Your specific water quality may be harder or softer.
Adjust the deliming interval to your specific water
quality.
NOTE: If you have the oven connected to a filter
system, the water hardness may be reĆ
duced. Check with filter supplier for deĆ
tails.
Over 14 gpg
Extremely Hard Setting A
10 to 14 gpg Very Hard Setting B
7 to 10 gpg Hard Setting B
3 to 7 gpg Moderately Hard Setting C
Less than 3 gpg Slightly Hard Setting C
Canadian Water Quality
Most of Canadian water contains 112 mg/L (8 gpg).
This would place Canada in the hard water catagory
and setting B should be used. If your water exceeds
196 mg/L (14 gpg), setting A should be used.
Figure 22