-26-
Revision 4/F3576 © Moffat Ltd, December 2004
6.3 REPLACEMENT
6.3.1 POWER / ROAST SWITCHES
6.2.7 CONTROL PANEL—REAR
1) Open the control panel (refer 6.2.1).
2) Disconnect the wires from the faulty
switch.
3) Press in the locking tabs at top and bottom
of the switch and from rear push switch
through front of control panel.
6.3.2 LIGHTS / WATER SWITCHES
1) Open the control panel (refer 6.2.1).
2) Disconnect the wires from the faulty
switch.
3) Press in the locking tabs at top and bottom
of the switch and from rear push switch
through front of control panel.
6.3.3 TIME UP / ROAST INDICATORS
1) Open the control panel (refer 6.2.1).
2) Disconnect the wires from the faulty
indicator.
Figure 6.2.9
4) Replace and reassemble in reverse order.
4) Replace and reassemble in reverse order.
Figure 6.3.1
Locking
tabs
Figure 6.3.2
Locking
tabs
Power Switch
Power Indicator
Thermostat
Heating Indicator
60 Minute Timer
Time Up Indica-
Hold Indicator
3 Hour Timer
Roast Switch
Lights Switch
Water Switch