-29-
Revision 4/F3576 © Moffat Ltd, December 2004
Two
screws
1) Gain access to the oven burners (refer
6.2.6).
2) Remove the four screws securing the pilot
burner to the main burner aeration slide.
1) Gain access to the oven burners (refer
6.2.6).
2) Remove the screw holding the electrode
positioning bracket to the housing on the
inside of the oven.
3) Pull the fan and motor assembly into the
oven as pictured below, and disconnect
the wiring. The fan motor unit can now be
removed from the oven.
4) Slacken the two socket head grub screws
spaced at 90
o
on the fan boss.
Figure 6.3.14
5) Remove the fan from the motor shaft.
NOTE:
Use of a fan puller is recommended
for removal of the oven fan.
6) Re-assemble in the reverse order.
NOTE:
No lubrication of either the fan or
motor is required as they are both self
lubricating.
Figure 6.3.15
6.3.12 IGNITION ELECTRODES
3) Remove the oven right hand side panel
(refer 6.2.4).
4) Remove the two screws securing the
electrode mounting bracket to the right
hand insulation panel.
5) Transfer the wires to the new electrode
assembly and reassemble in reverse
order.
NOTE:
Ensure to correctly set electrode
gapping when installing new electrodes
and test before fully re-assembling oven.
Between SPARK and EARTH (centre) 3-5mm
Between EARTH and main burner 7-10mm
Between SENSOR and EARTH 10-12mm
Between SENSOR and main burner 7-10mm
Figure 6.3.16
Figure 6.3.17
Screw
6.3.13 PILOT BURNER
Figure 6.3.18
3) Slide the pilot burner off the pilot injector.
4) Replace pilot burner and reassemble in
reverse order.