-7-
Revision 4/F3576 © Moffat Ltd, December 2004
LOCATION
This oven must be installed in an area of
adequate air supply. The following minimum
clearances for air openings, servicing,
operation and installation are to be adhered
to:
Rear 100 mm
Left-hand side 100 mm
Right-hand side 300 mm
Top 1200 mm
OVEN INTERNAL DIMENSIONS
Width 730 mm
Height 490 mm
Depth 600 mm
Oven Volume 0.21 m³
OVEN RACK SIZE
Width 710 mm
Depth: 520 mm
GAS SUPPLY SPECIFICATION OPTIONS
Natural LPG
Input Rating 73 MJ/hr 73 MJ/Hr
69 000 Btu/hr 69 000 Btu/hr
20.3 kW 20.3 kW
Gas Rate 1.90 m³/hr 1.40 kg/hr
Inlet Pressure 1.13 kPa 2.75 kPa
4.5”w.c. 11.0”w.c.
Burner Pressure (From S/N 275353)
0.90 kPa 2.50 kPa
3.6” w.c. 10.0” w.c.
(Up To S/N 275352)
0.89 kPa 2.65 kPa
3.6” w.c. 10.6” w.c.
GAS CONNECTION SPECIFICATIONS
3
/
4
” BSP female
MAIN BURNER INJECTOR ORIFICE SIZE
LPG 1.20 mm
Natural 1.90 mm
PILOT BURNER INJECTOR ORIFICE SIZE
LPG 0.70 mm
Natural 1.10 mm
ELECTRICAL SUPPLY SPECIFICATION
OPTIONS
230-240 V AC, 50 Hz, 2.1 A, 1P+N+E
220 V AC, 60Hz, 2.1 A, 1P+N+E
ELECTRICAL PLUG SPECIFICATION
REQUIREMENTS
Australia AS 2124, 10 Amp, 3 pin
New Zealand AS 2124, 10 Amp, 3 pin
Other Countries Type to meet country
standards
WATER SUPPLY CONNECTION
Max Pressure 550 kPa / 5.5 bar / 80 psi
Min Pressure 100 kPa / 1.0 bar / 15 psi
AUTOMATIC IGNITION CONTROL
Lock-out condition after burner ignition failure.
No re-ignition attempt.
Units from S/N 205337: 1 re-ignition attempt
in the event of flame loss during burner
operation. Lock-out condition if re-ignition
failure.
NOTE:
Refer to Appendix B for further
ignition control specifications.