4-24 OPERATION
C
ONTROL
INSTRUCTIONS
SCALE COUNTS
COUNTS SOFTKEY
By pressing the soft key located under the word Counts on the
Scale Value Screen, the scaled counts are available. Additional
information on how to access this screen can be found in the
Maintenance Area of the operator display overview in
Appendix E of this manual.
The number shown is the current count value, i.e. the pulses
per revolution of the encoder. For example a 3000 pulse quad-
rature encoder will produce 3000 x 4 channels or 12000
counts. A cursor will appear in the least significant digit. The
user has a choice of ways to adjust this number.
Exit or Prev, if no change is required press Exit or Prev to
return to the Scale Value screen.
Raise will increase the value by 1. The key can be pressed
once for each 1 increment required or held down to scroll up.
Releasing the key will freeze the value at the last value.
Lower will decrease the value by 1. The key can be pressed
once for each 1 decrement required or held down to scroll
down. Releasing the key will freeze the value at the last value.
Numeric keys
Key in the count desired and press enter. If you require 12000
counts you must key in 12000 and then press enter.
Enter or Delete?
If the keyed in number is correct press the enter key for it to
be accepted and return to the Scale Value screen. If it is wrong
press the delete key and the previous value will reappear.