Evolution Technologies Instant, Freshbrew & Espresso (B2C) Machine Coffeemaker User Manual


 
2. Freshbrew & Espresso Machines: Evolution machines fitted with a paperless
freshbrew brewer or CoEx® brewer must be connected to the water supply via
a water filter. This filter must be of food grade quality and able to remove
temporary hardness (scale), heavy metals (lead, copper, iron, cadmium), chlorine
and any organic pollutant’s/discolouration. Crane Merchandising
Systems recommend and supply the Brita AquaQuell water
filter.
Warning! If the machines indicated above are connected to the water supply
and used without a water filter as specified, the warranty will be void.
3. Connect the flexi-hose supplied with the machine to the stopcock ensuring that
the seal supplied is fitted correctly. Flush the system (several gallons) before
connecting the machine.
3. Connect the hose to the inlet valve located on the rear of the machine. Ensure
that the seal is correctly fitted. Ensure that all water supply fittings are tight.
4. Turn on the water supply at the stop tap and check for leaks. Prime the water
filter (where fitted) following the instructions supplied by the filter manufacturer.
2.3 Connecting the Electrical Supply
Safety First! The machine must be earthed. On no account should it be
earthed only to the water supply pipe.
The machine must be connected to a 230 Volt 50Hz 13 amp fused switched socket
outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved
13 amp fused plug.
Important: If the mains lead becomes damaged in any way it must be replaced by a
special lead available from the manufacturer.
2.4 Commissioning Procedure
The following procedure must be carried out by a trained installation engineer before
the machine can be used for the first time. Ensure that the electrical and water services
to the machine are connected correctly. Check for leaks in the water supply.
1. Open the front door of the machine. Fit the door switch bracket to the door using
the two screws provided. Ensure that the bracket will operate the door switch
when the door is closed. Switch on the electricity supply.
2. Ensure that the waste bucket is fitted correctly. Clip the level detector and
overflow pipes correctly onto the rim of the bucket.
Operators Manual
8