The machine is factory set to enable data transfer via the optical DDCMP link. To
change this to the DEX setting, press the (Edit) key to access the menu and the
(up) key to select DEX (indicated by the filled radio button. Press the (Edit)
key to save the selection.
N.B. Even if the default is set to DDCMP, once the controller detects a DEX
activity, it will automatically switch to the other mode. However, setting the
default to the correct protocol will speed up response time.
The operator can now download data from the machine by plugging a DEX
enabled device into the DEX port (J36) on the I/O board, located on the rear of
the door.
2. DTS Audit List: From this sub-menu the
operator can select which data is transferred
from the machine to a DEX/DDCMP data
carrier. Scroll down and highlight DTS Audit
Data. Press the (Edit) key to access the menu.
The LCD will display the screen as shown.
All data and events fields within a vending machine are assigned a unique code
determined by the Standard. From this sub-menu the operator can choose to
allow all fields to be available for download by pressing the START/? key or
scrolling through the list and adding an X to the required fields.
3. CA304 Data Type: This sub-menu determines whether the the data will be
displayed as currency or numerical, for example, assuming that the value of pound
coins in the machine is £3.00, when set to currency CA304 will read 300 in the
DEX/DDCMP report. When set to numeric it will read 3.
4. Data Reset Mode: This field can be set to either AUTO or SAVE from within
the sub-menu. When set to AUTO, all resettable data will be reset after a
successful read.
5. Event Reset Mode: This field can be set to either AUTO or SAVE from within
the sub-menu. When set to AUTO, all event data will be reset after a successful
read.
6. Printer Baud Rate: This allows the operator to set the correct baud rate for
a serial printer if one is to be used. It is important for this to be set correctly to
ensure successful data transfer.
4. Backup/Restore: This menu allows the operator to manually backup information
stored in the machines memory to the controller board.
Operators Manual
52
DTS Audit List
Start
(
?
)
=Set or Clear All
ID 1
ID 2
ID 3
ID 4
ID 5
X
X
X
X
X