Evolution Technologies Instant, Freshbrew & Espresso (B2C) Machine Coffeemaker User Manual


 
5. Carefully remove the brewer waste container from
the machine and empty the contents. Push up and
remove the waste chute (a) from the machine.
Wash both the waste container and chute thoroughly
and if necessary sanitise using the diluted bactericidal
cleaning solution. Rinse in clean water.
Dry both components using a clean, dry cloth and refit
to the machine.
N.B. Every time that the brewer waste container is emptied the waste counter
must be reset. Restore power to the machine using the safety key and press
button 12 on the service keypad. Two audible bleeps confirm that the counter
has been reset to zero.
6. Refit the CoEx® brewer unit into the machine. Slide
the unit into place until it ‘clicks’ into position. Refit the
coffee dispense pipe to the brewer outlet as shown.
Ensure that both the fresh bean container and fresh
ground coffee canister are filled with correct product.
Refill if necessary following the procedures outlined on
pages 22 and 23.
4.9 CoEx® Espresso Brewer Unit - Weekly Cleaning Procedure
The following procedure must be carried out on a weekly basis. Proceed as follows:-
1. Open the front door of the machine and insert the safety key to restore power
to the machine.
Caution: Ensure that a suitable container is placed under the dispense
position. Keep hands away from the dispense area whilst the cleaning cycle is
in operation.
2. Press and release button 11 on the service keypad. The
LCD will display the message ‘Please Place
Cleaning Tablet in Brewer’.
Take one cleaning tablet (supplied in packs of 30 - CMS
part no. ZC10598000) and place it into the brewer
piston chamber as shown.
Operators Manual
29
a