Cornelius R-404A REFRIGERANT Beverage Dispenser User Manual


 
33 312028000
1. To disconnect soft drink tank from Unit
syrup system.
A. Disconnect liquid disconnect from soft drink tank. NOTE - Disconnecting liquid quick
disconnect from soft drink tank first prevents syrup from backflowing through Unit syrup flow
regulator, which may alter regulator adjustment.
B. Second, disconnect CO
2
quick disconnect from soft drink tank.
2. To connect soft drink tank into Unit syrup system.
A. First, connect CO
2
quick disconnect to soft drink tank to pressurize tank.
B. Second, connect liquid quick disconnect to soft drink tank.
Syrup supply should be checked daily and if necessary, replenished as instructed.
PRODUCT FLAVOR CHANGE
Perform syrup flavor change as instructed.
CHECKING CO
2
SUPPLY
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
Make sure CO
2
cylinder shutoff valve is fully opened and regulator assembly 1800-psi gage indicator is not in
shaded (‘‘change CO
2
cylinder’’) portion of dial. If so, CO
2
cylinder is almost empty and must be replaced as
instructed.
CLEANING AND SANITIZING
DAILY CLEANING
Daily or more often if necessary, wash all external surfaces of Unit, rinse with clean water, then wipe dry with
clean soft cloth. DO NOT USE ABRASIVE CLEANERS. Wash the drip tray and cup rest with warm water and
mild detergent, then rinse with clean water.
SANITIZING
The Unit syrup systems should be sanitized as instructed every 120-days and before and after storage periods
following parent company requirements and sanitizer manufacturers recommendations. Sanitize syrup systems
as instructed.
CLEANING CONDENSER COIL
The FCB Dispenser refrigeration system is equipped with a condenser coil (see Figure 6) that is cooled by two
condenser coil fans. Circulating air, required to cool the refrigeration systems condenser coil, is drawn in
through a grilled panel on the right-hand side and is exhausted out through the opposite side and back grilled
panels. Restricting air circulation through the Unit will decrease its cooling efficiency. THE CONDENSER COIL
MUST BE CLEANED PERIODICALLY AS INSTRUCTED IN the SERVICE AND MAINTENANCE section.
LUBRICATION
Carbonator pump motor must be lubricated as instructed on the motor.