Cornelius R-404A REFRIGERANT Beverage Dispenser User Manual


 
35 312028000
PROGRAMMING ‘‘SLEEP’’ (SLEEP TIME) INTO UNIT
‘‘SLEEP’’ (SLEEP TIME) may be programmed into Unit to occur any time of the day after the Unit automatic
defrost cycle has occurred. Unit will shut down (go into sleep time) and will not wake up (return to normal opera-
tion) until programmed ‘‘WAKE UP’’ (WAKE UP TIME) has occurred. Program ‘‘SLEEP’’ (SLEEP TIME) into
Unit as instructed in the INSTALLATION section.
PROGRAMMING ‘‘WAKE UP’’ (WAKE UP) TIME INTO UNIT
‘‘WAKE UP’’ (WAKE UP TIME) may be programmed into Unit to occur any time of the day to wake Unit up (re-
turn to normal operation) after ‘‘sleep time’’ has occurred. Program ‘‘WAKE UP’’ into Unit as instructed in the
INSTALLATION section.
PROGRAMMING POINT OF SALE MESSAGE DISPLAY
Three point of sale display messages are available to choose from and may be programmed into Unit by placing
No.1 and No. 2 switches on DIP SWITCH assembly on master circuit board in appropriate positions. Program
point of sale display messages into Unit as instructed in the INSTALLATION section.
ADJUSTING ‘‘VIS SET’’ (PRODUCT VISCOSITY) OF DISPENSED PRODUCT
Adjusting ‘‘VIS SET’’ (PRODUCT VISCOSITY) determines what product consistency of the dispensed product
will be present in each freeze cylinder. Adjust ‘‘VIS SET’’ (PRODUCT VISCOSITY) of the dispensed product as
instructed in the INSTALLATION section.
VIS READ (ACTUAL VISCOSITY READOUT) OF PRODUCT IN FREEZE CYLINDERS
VIS READ (actual viscosity readout) may be brought up on the message display to actually read the viscosity
(product consistency) of product in the freeze cylinders while the Unit is in operation as instructed in the
INSTALLATION section.
DISPLAYED EVAPORATOR REFRIGERATION COILS INLETS AND COMMON OUTLET
SENSORS TEMPERATURES
Evaporator refrigeration coils inlet and common outlet temperature readings in degrees Fahrenheit may be dis-
played on message display as instructed in the INSTALLATION section.
‘‘VOLTAGE’’ (DISPLAYED VOLTAGE READOUT)
Displayed voltage readout may be displayed on message display as instructed in the INSTALLATION section.
PROGRAMMING COMPONENTS ‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) INTO UNIT
‘‘DIAGNOSE’’ (DIAGNOSTIC MODE) may be programmed into the Unit to check certain components for
operation. Program ‘‘DIAGNOSE’’ into the Unit and check components for proper operation as instructed in the
INSTALLATION section.
DISPLAYING ‘‘TOTALS’’ (DISPLAYED CYCLES AND HOURS TOTALS) ONTO MESSAGE
DISPLAY
‘‘TOTALS’’ (DISPLAYED CYCLES AND HOURS TOTALS) may be displayed on the message display as
instructed in the INSTALLATION section.