Lexmark C762 Range User Manual


 
PostScript
4-69
MaxSourceList integer (Read-only) See Table C-4 on page C-9 for the default value
of your printer.
MaxUPathCache integer Maximum bytes occupied by the user path cache.
Legal value: Any non-negative integer.
PageCount integer (Read-only) Total number of pages that have been printed.
PanelCode
1
string (Read-only) Version of the operator panel code.
PrinterCode
1
string (Read-only) Firmware version of the printer controller card.
PrinterName string Initialized from the printer name stored in NVRAM (the default
name of the printer). If this parameter is set to a zero length
string, the PrinterName is set to the value of the product
string in statusdict.
Legal value: Any string of 32 or fewer non-null characters.
RamSize integer (Read-only) Total amount of memory (in bytes) installed in the
printer.
RealFormat string (Read-only) Preferred representation for real numbers in
binary encoded tokens.
Revision integer (Read-only) The current revision level of the machine-
dependent portion of PostScript emulation.
SearchBuiltinFontsFirst
1
boolean Controls the device search order the interpreter uses to
locate fonts.
SerialNumber
1
string (Read-only) Serial number of your printer.
StartJobPassword string (Write-only) Controls the ability of the startjob operator to
alter initial Virtual Memory (VM).
Legal value: Any integer or string of 32 or fewer non-null
characters. An integer is converted to a string.
StartupMode integer Controls the system start file (Sys/Start) during PostScript
emulation initialization. Also, controls the job start file (Job/
Start) before each print job.
0 Disable use of Sys/Start file and Job/Start file.
1 Sys/Start file executes (if present on disk or flash).
10 Job/Start file executes before each user job.
11 Both files run (a combination of 1 and 10).
Legal Values: 0 <= x <= 255. Values other than the four listed
are equivalent to 0.
Note: If both flash and disk have a Sys/Start file and Job/Start
file, the value of the SearchOrder for the two devices
determines which file is executed.
StaticRamSize
1
integer (Read-only) Amount of static memory (in bytes) on the
controller board.
Table 4-10: PostScript Emulation System Parameters (Continued)
Key Type Definition
1
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 2016.
2
These parameters are available with the Adobe PostScript Language Supplement 3010.
3
These parameters are Lexmark-specific and are in addition to the Adobe PostScript Language Supplement 3010.