Lexmark C762 Range User Manual


 
PostScript
4-83
Device Parameters for the Communication Device %PrintServer%, %PrintServerA%, %PrintServerB%,
%PrintServerC%, %PrintServerD%
(%PrintServer_NV% and %PrintServer_Pending% contain the same parameters)
DelayedOutputClose boolean Selects how the printer manages the port at the end of each print job. Supported values are:
True An end-of-file message is not sent until the current job and all preceding jobs
finish printing.
False An end-of-file message is sent as soon as a job finishes executing in the
interpreter, whether or not that job has finished printing.
This value is set independently for each port.
Enabled boolean (Read-only)
Supported values are:
True
False
Filtering name Indicates if the input needs further filtering before the data can be correctly processed.
Supported values are:
InterpreterBased
None
Note: Setting this variable changes the value of the corresponding %RemotePrinter%
device.
HasNames boolean (Read-only) Always returns False.
Interpreter name (Read-only)
Supported values are:
PostScript
AutoSelect
PCL
PPDS
On boolean Designates if the communication channel is On and able to receive and send data.
Supported values are:
True Data is sent and processed.
False Data is lost.
PortLocation string (Read-only) Designates the physical location of the port related to the parameter set.
Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
Type name (Read-only) Always returns the value of /Communications.
Table 4-11: PostScript Emulation Device Parameters (Continued)
Key Type Definition