3-4
SECTION 3
OPERATION
III. STEP-BY-STEP OPERATION
A. Startup Procedure
1. Turn on the main disconnect switch / circuit breaker.
2. Open the manual gas supply valve.
3. Turn the blower switch to "I" (on)
4. Set the temperature controller to the desired baking
temperature. (Refer to paragraph B for Temperature
Controller Operating Instructions.)
Figure 3-6. Control Panel
0
I
0
I
0
I
RESET
Middleby Marshall
ALM
HEAT
260
S E T P T
1
C
Oven Control Panel
Conveyor
Speed
Controller
(Tri Tandem /
Quad Tandem
version shown)
Conveyor
Switch
Heat
Switch
Blower
Switch
Lighted Ignition
Reset Switch
Temperature
Controller
Service Key
Conveyor Speed Indicator
(Tri Tandem / Quad Tandem
version shown)