Middleby Cooking Systems Group PS360/PS360WB Oven User Manual


 
4-4
SECTION 4
MAINTENANCE
II. MAINTENANCE - MONTHLY
WARNING: Before performing any further
maintenance, turn the main power switch off.
NOTE: The interior may require cleaning more than once
a month, depending on the volume of baking.
To clean the interior, you must disassemble some parts
of the oven.
A. Removing conveyor from oven for cleaning
1. Remove the crumb pans (Tandem and Double Tan-
dem Ovens only). Refer to the Daily Maintenance
procedures.
2. Remove conveyor extension covers from both ends of
oven (Figure 4-7) (Tandem and Double Tandem Ovens
only).
Figure 4-7. Conveyor Extension
Cover Removal
3. After removing the bottom shield (located below the
shroud) by removing its three screws, remove the con-
veyor motor shroud. Loosen the hanger screw; then, lift
and remove the motor shroud.
4. Remove the end plugs from the oven side with the
conveyor drive motor.
5. Release the tension from the conveyor drive chain, as
follows:
Tandem and Double Tandem Oven:
Lift, and push, the conveyor assembly slightly into the
oven.
Tri Tandem and Quad Tandem Oven:
Loosen the mounting bolts of the conveyor drive motor.
Shift the motor to release the drive chain tension.
6. Detach the drive chain from the conveyor drive shaft
sprocket.