4-5
SECTION 4
MAINTENANCE
NOTE: The conveyor assembly of a tandem or a double
tandem oven can be removed from either end of oven. If
you are removing the conveyor from the end of the
oven without the drive motor, the drive sprocket as-
sembly must be removed by loosening the 3/32" set
screw on the conveyor drive shaft collar. Then, remove
the drive sprocket assembly from the end of the shaft.
7. Pull the conveyor belt until its master links are near the
end of the upper belt surface. Disconnect the master
links. (Refer to the later procedure "E. Conveyor belt link
removal", in this section, for additional details.)
8. Remove the conveyor belt by rolling it into a bundle.
Place the belt in a safe location.
9. Slide the conveyor frame sections out of the oven,
placing them on the floor for cleaning.
NOTE: Tandem and Double Tandem Ovens - Conveyor
frame sections are connected to each
other with hinges. The conveyor frame
must be removed as a unit.
Tri Tandem and Quad Tandem Ovens - Conveyor
frame sections are separate and must be
removed from both ends of the oven.
10. For a Quad Tandem oven, remove the two transition
side panels. Then, slide out the top transition panel to
obtain acces to the conveyor frame sections for removal.
(Refer to pages 2-19 through 2-21 for illustrations of
these oven components and text that clarifies the proce-
dure.)