Model C300Important: To the Operator
9. BRL NOT COOLING - A freezing c ylinder
check has been established for the AUTO
mode of operation. If a freezing cylinder enters
the AUT O mode, the control will check product
temperature. After five m inutes, it will again
check product temperature. If pr oduct
temperature does not drop in that five minute
time span, the freezing cylinder will shut down
and t his message will appear on the fault
screen. F or this check to be valid, the product
temperature must b e above 4 0_F(4.4_C).
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR +++ SEL
10. BRL TEMP 2 HIGH - A maximum allowable
product temperature has been es tablished t o
prevent product from excessive heating. If the
product exceeds 120_F(49_C) temperature for
any reason (in any mode of operation), the
entire unit shuts down.
FAULT DESCRIPTION
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR +++ SEL
Faults, w hen corrected, are cleared from the fault
description screen, with the following exception:
BRL NOT COOLING. This fault r equires the
operator to press the OFF (<- - ) key (when in the
F AULT DESCRIPTION screen) in order for the fault
to discontinue.
To s ee if there is more than one fault i n either
freezing cylinder, p ress the PRIME ( + + +) key. To
return to the OPERATOR MENU, press the MENU
(SEL) key once. To return to the Main Screen, use
the AUTO (- - >) key to cycle to MENU ITEM A,
then press t he MENU (SEL) key.
Screen C is SET CLOCK.UsetheAUTO(- ->)
and O FF (<- - ) keys to plac e the cursor under the
element to be set (hours, minutes, month, day, or
year). Use the PRIME (+++) and BEATER ( - - - )
keys to increment or decrement t he value. Press the
MENU (SEL) key to advance to the Daylight Saving
T ime screen.
Note: The clock is programmed with military time.
SET CLOCK
14
:30 6/25/01
<- - - -> +++ - - - SEL
This screen will appear if an inv alid date is entered.
(example: If the date entered exceeds the days of
that month.)
SET CLOCK
14
:30 02/31/01
INVALID DATE
SEL
This screen allows the Daylight Saving Time options.
If the Daylight Saving Time option is enabled, then
the time will be advanced by one hour at 2:00 a.m.
on t he first Sunday in April, and will be retarded by
one hour at 2:00 a.m. on the l ast S unday in October .
DAYLIGHT SAVING TIME
ENABLE
DISABLE
<- - - -> SEL
Screen D is MANUAL DE FROST. This screen
allows the operator t o manually defrost the left side
of the unit.
Place the cursor under YES, press the MENU (SEL)
key, and the c ommand will be executed.
MANUAL DEFROST
LEFT SIDE YES
NO
<- - - -> SEL