Taylor C300 Freezer User Manual


 
29
Model C300 Operating P rocedures
080507
Cleaning
Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2
gal. [7.6 liters] of Stera- SheenR) in a c lean, empty
pail. USE WARM WATER AND FOLLOW THE
MANUFACTURER’S SPECIFICATIONS.
Important: Make sure the cleaner is completely
dissolved.
Step 2
Place the syrup line with the old s yrup connector into
the pail of cleaner.
Step 3
To plac e the left freezing c ylinder in the SANITIZE
mode, press the MENU (SEL) k ey. Move the cursor
by pressing the AUTO (- - >) key until the third line
indicates RINSE / SANITIZE. Press the MENU
(SEL) key. Move the cursor under the w ord
“SANITIZE”.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - - -> SEL
Pressing the MENU (SEL) key will give you the
option to sanitize the left cylinder. Move t he cursor
under th e word “YES”. Pressing the M ENU (SEL)
key a t this time will start the flow of cleaner/sanitizer
through th e syrup system into the freezing cylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - - -> SEL
Repeat this procedure for the right side freezing
cylinder.
Step 4
Open the prime plugs. Allow each cylinder to fill
approximately 2/3 full. Clos e each p rime plug.
Step 5
Continue filling the freezing c ylinders with sanitizing
solution until the solution purges out of each relief
valve, and begins draining into the front drip tray.
The relief valves are located at the top of each m ix
tank. Press the OFF (<- - ) key.
Step 6
Press the BEATER (- - - ) key to agitate the solution
in each freezing c ylinder for five minutes.
Figure 44
Step 7
With a pail beneath the door spouts, open the draw
valves and drain all the solution f rom t he the
freezing cylinders. Press the OFF (<- - ) key and
close the draw valves.
Disassembly
Step 1
Be s ure the control s witch is in the OFF position.
Open the draw valves to make sure all pressure has
been relieved.
Step 2
Open the prime plug. Leave the prime plug open
when removing the freezer door to insure t hat all
pressure is relieved f rom t he freezing cylinder.
Step 3
Remove the following parts from the freezer and
take them to the sink for brush cleaning.
S handscrews
S freezer door s
S beater assemblies and scraper blades
S drive shafts
S front drip tray
S splash shield