Taylor C300 Freezer User Manual


 
26
Model C300Operating P rocedures
Step 7
Drain the product f rom the syrup s ampling valve into
a cup. Close the syrup s ampling valve by turning the
handle t o the center position.
Figure 36
Step 8
Stir the finished product. Pour a small am ount of
product over the refractometer . The brix reading
should register 13 to 14. A reading higher than this
would cause a darker, richer product. The
refrigeration system would have to run longer to
freeze the excess syrup. A reading lower than this
could cause a freeze- up in the freezing cylinder
because o f the excess water.
Figure 37
Step 9
To adjus t the brix, turn the adjustment screw located
behind t he drip tray s helf. Clockwise adjustments
increase the amount of syrup to water, and
counterclockwise adjustments decrease the amount
of syrup to water. Adjust the screw in small
increments and check the brix again.
Figure 38
Repeat this step until a correct br ix reading is
registered.
Step 10
Once the proper brix has been achieved, turn the
handle “up” to allow product to flow to the mix tank.
Figure 39