Taylor C300 Freezer User Manual


 
24
Model C300Operating P rocedures
Press the MENU (SEL) key.
Move the cursor under the word “SANITIZE” by
pressing the OFF (<- - )key.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - - -> SEL
Step 7
Pressing the MENU (SEL) key will give you the
option for sanitizing the left freezing c ylinder. Move
the cursor under the word “ YES”. Pressing the
MENU (SEL) key at this time will start the flow of
sanitizing solution into the left freezing c ylinder.
SANITIZE
LEFT SIDE YES NO
---
<- - - -> SEL
Repeat Steps 6 - 7 for the ri ght side freezing
cylinder.
SANITIZE
RIGHT S IDE YES NO
---
<- - - -> SEL
Step 8
Open the prime plugs. W hen sanitizing solution fills
the freezing c ylinders appr oximately 2/3 full, close
the p rime plugs.
Figure 29
Step 9
Continue filling the freezing c ylinders with sanitizing
solution until the solution purges out of the relief
valve a t the top of the mix tank, and begins draining
into the front drip tray. Press the OFF (<- - ) key.
Step 10
Press the BEATER (- - - ) key. Agitate the solution
in t he freezing cylinders for f ive minutes.
Figure 30
Step 11
With a pail beneath the door spouts, open the draw
valves and drain all the solution f rom t he freezing
cylinders. P ress the OFF (<- - ) key and close the
draw valves.
Figure 31
Step 12
Disconnect t he syrup connectors in the sanitizing
solution.