090219
Initial Freezing Cylinder Cleaning
Due t o the types of products used in FCB
equipment, it is imperative that the freezing cylinder
and t he inlet tube be thoroughly brush cleaned,
rinsed, and sanitized before running any product.
Prepare a cleaning solution, using 2 oz. of liquid
detergent in 2 gallons of warm water. Us ing this
solution, brush clean the freezing c ylinder and the
inlet tube. Rins e the freezing cylinder and the inlet
tube with clean water and then s anitize, using the
sanitizing procedures outlined in this Operator
Manual, starting on page 23.
Refrigerant
In consideration o f our environment, Taylor
proudly uses only earth friendly HFC refrigerants.
The H FC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Deplet ing Potential
(ODP) of zero (0).
However , any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder t o approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms
to the AHRI standard 700 specification. The use of
any other refrigerant may e xpose users and
operators to unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious dam age to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately wit h cold water. If bur ns are severe,
apply ice packs and contact a physician
immediately.
Taylor reminds technicians to be awar e of
and in compliance with local government laws
regarding refrigerant re covery, recycling, and
reclaiming systems. For information regarding
applicable local laws, please contact your local
Taylor distributor.
W ARNING: R404A refrigerants used in
conjunction with polyolester oils are e xtremely
moisture absorbent. When opening a refrigeration
system, the maximum time the system is open must
not exceed 15 minutes. Cap all open tubing to
prevent humid air or water from being absorbed by
the o il.