16 INFO MODE
Test Mode - Self Test
From TEST MODE, press the R4 soft key to access the
“Self Test” screen (Figure 15). From the “Self Test”
screen:
- L1 soft key initiates a comprehensive self test.
The oven will check the door switches, blowers,
magnetrons, and heaters in sequence.
- L2 soft key initiates a door switch test only.
- L3 soft key initiates a blower test only.
- L4 soft key initiates a magnetron test only.
- L5 soft key initiates a heater test only.
When each test completes, the oven will display
PASS or FAIL.
Test Mode - Manufacturing Mode
Press the R3 soft key to place the oven in
MANUFACTURING MODE (Figure 16). When in
MANUFACTURING MODE
, the following tests and
settings can be accessed:
- Microwave leakage test
- Microwave power test
- Burn in
- Serial number edit
- Temperature measurement (F or C)
- Self test (same as
TEST MODE).
- Erase/default oven settings
Microwave Leakage Test
Press the L1 soft key to initiate the microwave
leakage test. The oven will warm up to 500°F
(260°C). When warmup is complete, insert the
water load. Follow the steps on page 27.
Microwave Power Test
This test should only be performed by the
manufacturer.
Burn-In
Press the L3 soft key to initiate a 25-minute burn-in.
This feature helps ensure all cavity walls reach ther-
mal equilibrium before testing is conducted.
ERASE SETTINGS
ERASE COUNTERS
AND FAULT LOGS
COMPLETE ERASE
Figure 18: Erase Settings
R1
R2
R3
R4
R5
L1
L2
L3
L4
L5
_
SERIAL NUMBER EDIT
i 5 - D 1 0 0 0 1
CANCEL
SAVE
<>
Figure 17: Serial Number Edit
MAG TEST
HEATER TEST
AUTO TEST
DOOR TEST
BLOWER TEST
SELF TEST
P S M t H B T W
Figure 15: Self Test
R1
R2
R3
R4
R5
L1
L2
L3
L4
L5
R1
R2
R3
R4
R5
L1
L2
L3
L4
L5
BURN IN
MANUFACTURING MODE
MW POWER TEST
MW LEAK TEST
SERIAL NUMBER EDIT
FAHRENHEIT
SELF TEST
SETPOINT = 500F
ERASE/DEFAULT
Figure 16: Manufacturing Mode
R1
R2
R3
R4
R5
L1
L2
L3
L4
L5