28 OVEN SYSTEMS
5. Close the oven door and press the Enter key.
The microwave system will turn on.
6. Position the microwave survey meter as shown
in Figure 28, above.
7. Measure microwave emission around the door,
moving the meter sensor at 0.5 inches/second.
As microwave leakage is observed moving the
sensor at 0.5 inches/second, note any meter
spike areas that come close to 5mW/cm
2
for
later re-measurement.
8. Replace the water load every 60 seconds until
the test is completed, and also after scanning
the door.
9. Close the oven door and return the meter
probe to any "meter spike" areas and allow the
probe to remain in the "spike" area for 17
seconds. Note the highest reading obtained.
NOTE: There may be several places on the door
where this procedure needs to be done. If so, start
out with a fresh water load each time a new area is
measured, or if measurement of an area takes
longer than 60 seconds.
10. After each test is complete, open the oven door
and dispose of the hot water.
Troubleshooting
The following faults may occur in relation to the
oven door:
- F4: Monitor (see page 42)
The following issues may occur in relation to the
oven door:
- “Cook Door Open” message when door is
closed (see page 45).
Figure 28: Survey Meter Placement