Wolf ICBSO30-2U/S Microwave Oven User Manual


 
SETTING CONTROLS
For Temperature Probe feature with breads:
1)
Preheat oven to desired oven temperature
in
Bake
or
Bake Stone mode
.
2)
Place bread on bake stone or in oven in
bread pans.
3)
Bake 10 minutes at the desired oven
temperature.
4)
Insert probe sensor into the thickest part of
the bread.
5)
Using a dry potholder, lift the probe sensor
cover. Slide the probe connector into the
receptacle on the wall of the oven until it
snaps into place. Close the oven door.
6)
Touch
TEMP PROBE
. Touch number
pads for the end internal baking tempera-
ture 90˚C to 100˚C.
7)
Touch
ENTER
. The display shows the
oven temperature and the rising probe
temperature counting up to the doneness
setting.
8)
When the carving temperature is reached,
two chimes will signal. Remove probe from
the oven receptacle. The chime continues
every 10 seconds until the probe is
unplugged or until you touch
CLEAR
.
9)
To end this feature and turn the oven off,
touch oven
OFF
. Oven temperature
stays on even when probe is unplugged.
WOLF E SERIES BUILT-IN OVEN OPERATION
TEMPERATURE PROBE FEATURE
SETTING CONTROLS
For Temperature Probe feature with meats:
1)
Preheat oven to desired oven temperature
in desired mode.
2)
Place meat on a rack in the roasting pan.
Insert the probe sensor into the thickest
part of the meat as described in Tips For
Success on page 28.
3)
When the oven signals that preheat is
completed, use a dry potholder to lift the
probe sensor cover. Slide the probe connec-
tor into the receptacle on the wall of the
oven until it snaps into place. Close the
oven door.
4)
Touch
TEMP PROBE
. Touch number
pads for the carving temperature of the
meat. It is recommended to allow meat to
rest before carving.
5)
Touch
ENTER
. If
ENTER
is not
touched, the oven will automatically start
the Temperature feature in 8 seconds. The
display shows the oven temperature and
the rising probe temperature counting up
to the doneness setting.
6)
When the carving temperature is reached,
two chimes will signal. Remove probe from
the oven receptacle. The chime continues
every 10 seconds until the probe is
unplugged or until you touch
CLEAR
.
7)
To end this feature and turn the oven off,
touch oven
OFF
.
IMPORTANT NOTE:
If the probe connector is
not fully seated into the probe receptacle, then
you will hear an audio signal, and
PROBE
SHORTED
will show in display. Refer to the
Troubleshooting Guide on page 35.
Probe and probe sensor cover become
very hot. Handle with a dry potholder.
29