3-59
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Procedures
IDBMAN Messages
Explanation There is an internal error that caused an invalid bandwidth to be used for an aggregate
port. [chars] is the port-channel name. The ([dec] / [dec]) are the slot and port numbers (slot/port).
The last [dec] is the bandwidth.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 2-7.
Error Message IDBMAN-3-INVALIDPORT: [chars]: trying to use invalid port number [dec]
( Max [dec] ).
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 2960 switches.
Explanation There is an internal error that caused an invalid port number to be used by the software.
[chars] is the interface name. The first [dec] is the port number that is invalid, and the second [dec]
is the maximum allowed value for a port number.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 2-7.
Error Message IDBMAN-3-INVALIDVLAN: [chars]: trying to use invalid Vlan [dec].
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 2960 switches.
Explanation There is an internal error that caused an invalid VLAN to be used by the software.
[chars] is the interface name, and [dec] is the VLAN ID that is invalid.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 2-7.
Error Message IDBMAN-3-NOTANAGGPORT: [chars]( [dec] / [dec] ) is not an aggregate
port.
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 2960 switches.