Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Procedures
ILPOWER Messages
Error Message ILPOWER-4-LOG_OVERDRAWN: Interface [chars] is overdrawing power. it is
consuming [dec] milliwatts where as maximum configured power is ([dec])
milliwatts.
Note This message applies only to Catalyst 3750, 3560, and 3550 switches.
Explanation The powered device is drawing more power than the maximum powered configured on
the interface. [chars] is the interface, and [dec] is the maximum configured power.
Recommended Action Ensure that the correct power is budgeted for this interface based on the
powered-device electrical specifications or ratings. Otherwise, you might risk overloading the
switch. We recommend that you change the cutoff power value if needed.
Error Message ILPOWER-5-CLR_OVERDRAWN: Interface [chars] is NOT overdrawing power.
it is consuming [dec] milliwatts where as maximum configured value is ([dec])
milliwatts.
Note This message applies only to Catalyst 3550 switches.
Explanation The device connected to the Power over Ethernet (PoE) interface is consuming more
power than the maximum power allocation. [chars] is the interface. The first [dec] is the power being
consumed, and the second [dec] is the maximum allocated power value.
Recommended Action No action is required.
Error Message ILPOWER-5-CONTROLLER_OVERDRAWN: Interface [chars] is NOT overdrawing
power. it is consuming [dec] milliwatts where as maximum configured value is
([dec]) milliwatts.
Note This message applies only to Catalyst 3750, 3560, and 3550 switches.
Explanation The device connected to the Power over Ethernet (PoE) interface is consuming more
power than the maximum power allocation. [chars] is the interface. The first [dec] is the power being
consumed, and the second [dec] is the maximum allocated power value.
Recommended Action No action is required.
Error Message ILPOWER-5-DC_DISCONNECT: Interface [chars]: DC disconnect.
Note This message applies only to Catalyst 3550-24PWR switches.
Explanation The DC power has been disconnected.
Recommended Action No action is required.