Model EEE-141,142, 143, 144
7. If the oil has not pumped back to the proper level in the vat
during the SmartFilter Express™ process, press X button for
NO and pump runs for another 30 seconds.
9. Display shows “IS POT FILLED?” “YES NO”. Make sure
vat is full and then press
√√
√√
√ button and display shows and the
control returns to normal operation. Press X button and pump
runs for another 30 seconds. You can try to fill the vat 3 times.
Filter Error
10. After trying to fill the vat 3 times without success, the controls
then shows “CHANGE FILTER PAD?” “YES NO”. If
changing the filter pad at this time, press
√√
√√
√ and change filter pad
following the procedures in the Changing the Filter Pad Section.
Controls return to normal operation.
If filter pad is to be changed at a later time, press X button and
“CHANGE FILTER PAD?” reminder shows 15 minutes later.
11. During the next SmartFilter Express™ with a new filter pad, if
the vat is not filled after 3 tries, the display shows “FILTER
SERVICE REQUIRED-SEE TROUBLESHOOTING
GUIDE”.
If the “Service Required” message appears, then every 15
minutes the display shows “FILTER PROBLEM FIXED? YES
NO”. If the problem has not been fixed, press X button. Once
the problem has been resolved, press
√√
√√
√ and controls return to
normal operation.
To help ensure the vat fills completely, make sure filter pan is
cleaned at least daily, filter pad is changed, make sure JIB is full
and that “O” rings on the filter pan are in good condition.
209 3-12
3-11. SMARTFILTER EXPRESS™
(Continued)