Henny Penny EEE-142 Fryer User Manual


 
Model EEE-141,142, 143, 144
Mixed Filter Tracking
Filter After X Number of Loads
13b. Press button until “FILTER AFTER...” flashes in the
left display along, and the number of cook cycles between filters
shows in the right display. Press the product buttons, or the
and buttons, to change this value of 0 to 99 loads. This
needs set for each product.
>Load Compensation, Load Compensation
Reference, Full Heat, PC Factor<
14. Press button until “LD COMP” shows in the display,
along with the load compensation value. This automatically
adjusts the time to account for the size and temperature of the
cooking load.
Press the product buttons, or the and buttons, to
change this value of 0 to 20.
15. Press button until “LCMP REF” shows in the display
along with the load compensation average temperature. (if
load compensation is set to “OFF”, then “_ _ _” shows in
display and setting cannot be programmed) This is the average
cooking temperature for each product. The timer speeds up at
temperatures above this setting and slows down at temperatures
below this setting. Press the product button, or the and
buttons, to change this value.
16. Press button until “FULL HT” shows in the display along
with the full heat value in seconds, which means the heat is on as
soon as a timer button is pressed, for the programmed length of
time. Press the product buttons, or the and buttons,
to change this value of 0 to 90 seconds.
17. Press button until “PC FACTR” shows in the display along
with the proportional temperature, which helps to keep the oil
from over-shooting the setpoint temperature. Press the product
buttons, or the and buttons, to change this value of 0
to 50 degrees.
• Use button to go back to previous menu items.
Press button when finished with the current product, to
return to the “SELECT PRODUCT” step.
Press and hold button to exit PRODUCT PROGRAM
Mode.
5-1. MODIFYING PRODUCT
SETTINGS (Continued)
309 5-3