6-1. SPECIAL PROGRAM
MODE (Continued)
Autolift Enabled (SP-21)
Press button and “SP-21 AUTOLIFT ENABLED?”
flashes in the left display. Press the or buttons to
choose “YES LIFT” or “NO LIFT”. If fryer is fitted with the
auto-lift option, SP-21 must be set to“YES LIFT”, otherwise,
set SP-21 to “NO LIFT”.
Bulk Oil Supply (SP-22)
Press button and “SP-22 BULK OIL SUPPLY?” flashes
in the left display. Press the or buttons to choose
“YES SUPL” or “NO SUPL”. Set to YES if the oil is pumped
into the vats from an outside oil reservoir. Otherwise, set
SP-22 to NO.
Bulk Oil Disposal (SP-23)
Press button and “SP-23 BULK OIL DISPOSE?”
flashes in the left display. Press the or buttons to
choose “YES DISP” or “NO DISP”.Set to “YES DISP” if the
oil is pumped from the vats to an outside oil reservoir when
disarding the oil. Otherwise, set SP-23 to “NO DISP”.
Serial Number Log (SP-24)
Press button and “SP-24” and “S/N
√√
√√
√EDIT” flash in the
displays, along with the serial number of the unit. THIS
SERIAL NUMBER SHOULD MATCH THE SERIAL
NUMBER ON THE DATA PLATE, ON THE DOORS. IF
NOT, IT CAN BE RECORDED.
Program Code Change (SP-25)
This allows the operator to change the program code (factory
set at 1, 2, 3) used to access Product Programming and Level 2
Program Mode.
Press button and “SP-25” and “CHANGE MGR CODE?
1=YES” flash in the display. Press and “ENTER NEW
CODE, P=DONE, I=QUIT show scrolls through the display.
Press the product buttons for new code.
If satisfied with code, press and “REPEAT NEW CODE,
P=DONE, I=QUIT, shows in display. Press same code
buttons.