ELECTRICAL SUPPLY AND CONNECTION.
The electrical installation of the mixer must be in accordance with the current
edition of the IEE regulations for electrical equipment in buildings, Electricity at
Work Act 1989 and must conform to the requirements of the Local Electricity
Board.
The technical data shown in Table 1 details the electrical requirements for the mixer. Ensure
that the electrical supply agrees with the machine specification, prior to connection.
It is recommended the mixer is connected to a suitable external electrical isolator (see Table
1 for electrical data) fitted with a residual current device (RCD) rated at 30mA, to provide short
circuit and earth leakage protection.
The mixer is supplied with a cable and plug (which conforms to BS1363) and fitted with a
5A fuse (UK only).
COMMISSIONING AND OPERATING INSTRUCTIONS.
SAFETY INSTRUCTIONS.
THE ATTACHMENT AND/OR MIXER MUST ONLY BE USED BY A FULLY
TRAINED AND COMPETENT PERSON.
The following instructions must be observed when using the mixer:
Do not change speed while the mixer is operating.
Do not wear loose clothing.
Do not use the mixer or attachment if a fault develops or the machine is unsafe.
Do not access rotating parts.
Do not use excessive force when operating which could affect the stability of the mixer.
Do not operate the mixer if parts are disassembled.
Always use the attachment and/or mixer in a well lit area.
Always ensure the bowl, bowl clamps, agitator, attachment and guard are correctly fitted
to the machine.
Always disconnect the mains electricity supply before cleaning.
Always use the toggle switch ‘O’ to stop mixer.
Always clean the bowl, agitators and attachments after use.
Always clean mixer daily.
Always service the mixer and attachments at least twice a year depending on the frequency
of use.