Hobart N50 MIXER Mixer User Manual


 
– 18 –
FAULT FINDING.
Fault Possible cause Remedy
Machine fails to start. Blown fuse. Check and replace faulty
fuse.
Bowl support is not in the correct Place bowl in up position.
operating position.
Bowl guard is not in the correct Place guard in position.
operating position.
Speed selection lever not in correct Set to required speed
operating position. position.
Check gear level position. If not Move gear lever to
correctly engaged, mixer will not desired speed.
start.
Check that electrical supply is Plug in and switch on.
switched on.
Machine still fails to operate. Call local service centre.
Motor starts but Gear selection lever incorrectly Move to the correct speed.
shaft fails to turn. positioned.
If planetary shaft still fails to turn. Call local service centre.
RECOMMENDED SPARE PARTS.
Item Description Part number Qty
1 Bowl S-78575-2 1
2 ‘E’ dough hook D-478548 1
3 ‘D’ wire whip P-77764 1
4 ‘B’ flat beater (aluminum) P-9033 1
5 ‘B’ flat beater (stainless steel) R-62458 1
6 Guard, wire cage 478114 1
7 Agitator shaft spring V-111227 1
8 Drip cup P-21625-3 1
9 Thumb screw, attachment hub A-16951-4 1
10 End cover R-120433-2 1
11 Rubber foot 271650 4
12 Bowl retaining pin B-240185 2
13 Bowl clamp, LH C-291444-1 1
14 Bowl clamp, RH C-291444-2 1
15 Spring washer, bowl clamp B-291263 6
16 Lubricating grease, planetary and gearbox SU-E-4-14 0.6kg