Technical Information
CVA615 Coffee System
4.21 Water Valve
The Water Valve is attached to the output of the Coffee / Hot Water Flow
Through Heater. The valve is in a normally closed position.
When the Brew Unit is driven into the brew position the valve
mechanically opens and water is supplied to the Brew Unit. This
connection must be air / water tight to prevent air from entering the water
path, and / or leakage from the occurring.
Figure 4-22: Water Valve (Disassembled)
The two o-rings that form the seal to the brew unit can be accessed from
the front / inside area of the appliance - once the brew unit removed. To
access the upper seal, the heater must be removed from the appliance.
The Water Valve can be disassembled for service; parts can be replaced
individually.
44