Miele CVA615 Coffeemaker User Manual


 
Technical Information
CVA615 Coffee System
5.26 Brew Unit - Lubrication
1. Remove the Brew Unit – Refer to Section 5.20.
Note:
Check that the Brew Unit is in the basic position with the funnel slightly
lifted and the socket in vertical position.
2. Refer to Figure 5-22, lubricate the following:
Figure 5-22: Brew Unit Lubrication Points
A Joints
B Axel
C Tracks
D
Gas
k
et
3. Refer to Figure 5-23, lubricate the following:
Figure 5-23: Brew Unit Lubrication Points
E Bolt Assembly
F Joints
4. Return the brew unit into the appliance.
71