Taylor C717 Frozen Dessert Maker User Manual


 
Model C709
057010-33
06/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
BROWN
J2
J3
GND
+5V
J5
1 2 3 45 6
J6
1 2 3 45 6
L1
7
J7
1 2 3 45 6 7
3 1
5
J8
J9
J12
J11
1
23
45
678
J10
1
23
4
5
6
78
9
10
B
A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
7 8
J13
RED
WHT/RED
ON
OFF
BARREL
LIQUID
SOLENOID
HOPPER
LIQUID
SOLENOID
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
WHITE
M
AGITATOR
MOTOR
SEE
DETAIL
WHT
24 VAC
COM
BLU/WHT
WHT
BLK/BLU
HOPPER
HOT GAS
SOLENOID
BARREL
HOT GAS
SOLENOID
BLU
BLU
BEATER
MOTOR
INTERLOCK
N.O. SWITCH
USER
INTERFACE
BOARD
0
1
3
4
2
7
8
6
0
1
3
4
2
7
8
6
HOPPER
HOT GAS
SOLENOID
RELAY
BARREL
HOT GAS
SOLENOID
RELAY
- 8 LEDS
- LCD SCREEN
- 9 KEYS
- BEEPER
BLACK
BLU
TAN
WHT
BLK
GRA/BLK
GRA
BLU/WHT
BLU/WHT
BLK
YEL/BLK
BLK
GRA
BLU
BLU/WHT
BLU/WHT
BLK
BRN/WHT
BRN/WHT
BRN/WHT
BRN/WHTBRN/WHT
RED
CLR (+5v)
BLK (GRD)
BLU
BRN/WHT
HOPPER
GROUND
BLUE
GRA/WHT
WHT/BRN
BLK
LIV
SOLENOID
BLK
M
L2
L1
T1
T2
AIR COOLED ONLY
BLK
COMPRESSOR
CONTACTOR
RED
WHT
M
BLU/WHT
BLUE
AGITATOR MOTOR
DETAIL
SE
BLUE
WHT
RED
SNUBBER
WHT
ORN
TAN
BLACK
#3
#1
208
T3 L3
I3
I4
L3
BLK
BLK
BLK
BLK
BLK
BLK
L3
T3
BLK
*C708*
NO
NC
DRAW
SWITCH
C0M
PANEL
JACK
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
M
MIX
PUMP
MOTOR
BLK
BLU
23
4
RED
START
RELAY
ORN
PUR
YEL
WHT
FIG 2
ALTERNATE MIX PUMP MOTOR WIRING
A
LEFT SYRUP HEATER
THERMOSTAT
140° OPEN
100° CLOSE
WHT
WHT
O.T.
RIGHT SYRUP HEATER
THERMOSTAT
140° OPEN
100° CLOSE
WHT
WHT
O.T.
BLK
BLK
WHT
GRN
WHT
C
NO
200-240 VAC
012626
WHT
OPTIONAL HEATED SYRUP RAIL
WHT
GRN/YEL
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
EXTERNAL
GROUND
L2
GROUND FRAME SECURELY
L1
TERMINAL BLOCK
BRN/WHT
INTERFACE BOARD
POWER TRANSFORMER
BLK
ORN
RED
BLU
16V
L2
LOAD
LINEL1
L1 L2
240V
WHT
NOT
CONNECTED
WHT
WHT
GRN/YEL
GRN/YEL
BLK
GRN/YEL
BRN/WHT
POWER
SWITCH
DPDT
BLK
ON
OFF
RED
BLU
GRN/YEL
BLK
BLK
BLK
BLK
BLK
HOPPERBARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON
CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP/WHT
PRP/WHT
GRN/YEL
GRA/BLK
RED/BLK
NO
NC
BLK
DRAW
SWITCH
COM
RED
BLU
RED
BLU
RED
BLU
RIBBON CABLE
WHTWHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL
WHT
WHT
BLK
M
MIX
PUMP
MOTOR
(SEE FIG 2)
BLK
OVERLOAD
SWITCH
23
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
PUR
YEL
BARREL
SUCTION
SOLENOID
ORN
WHT
GRN/YEL
GRN/YEL
BLK
SV CABLE SV CABLE
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BRN/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2L1 T1
CONDENSER
FAN MOTOR
M
BLK BLK
BLUE
BLK
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
BLK
CLR
ONE SIDE OF A
TWO WIRE CORD
FUSE
15A
4 5
EMI FILTER
UVC4
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED- BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45
F (7 C)
FOR MORE THAN ONE HOUR OR ABOVE 41
F
(5
C) FOR MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED-NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2 PINS 1 AND 2
DOMESTIC CONFIGURATION-JUMPER INSTALLED.
HOPPER TEMPERATURE NOT DISPLAYED ON
SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE
WHEN A LOCKOUT CONDITION HAS OCCURRED/
STANDBY KEYS DISABLED.
YES
INTERNATIONAL CONFIGURATION-NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
NO
JP4
RESERVED (DO NOT USE)
NO
JP5
RESERVED (DO NOT USE)
NO
JP6
RESERVED (DO NOT USE)
NO
JP7
JUMPER INSTALLED DISABLES RESET.
NO
RTCK
RESERVED (DO NOT USE)
NO
DBGEN
RESERVED (DO NOT USE)
NO
INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1
RESERVED (DO NOT USE)
NO
W2
JUMPER INSTALLED-FORCE BRUSH CLEAN STATUS.
NO
W3
RESERVED (DO NOT USE)
NO
W4
JUMPER INSTALLED-OPEN ALL SOLENOIDS.
NO
W5
RESERVED (DO NOT USE)
NO
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
J10
PINS 1 & 2
JUMPER INSTALLED-ENABLES 59
F HOPPER
TEMPERATURE CHECK.
YES
PINS 7 & 8
JUMPER INSTALLED W/SWITCH-SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE YES
BLK
BLK
BLK
M
WHT
PANEL SPINNER OPTION
SEE FIG. 1
BRN/WHT
M
BLK
BLK
BLK
BLK
BLK
WHT
LINE
LOAD
LINE FILTER
SPINNER MOTOR WIRING
FIG. # 1
LINE
GRN/YEL
BLK
BLK
BLK
WHT
WHT
WHT
WHT
BLU/WHT
BLU
BLU
OPTIONAL
LOW PRESSURE
FAN SWITCH
WHT/GRA
BLU
BLU
WHT
L2
GRD
+5V
J2
J11J10
J7
J1
1
2
UNIVERSAL CONTROL PCB A.
BLK
CLR
J9
J12
SHIELD CUT
NO CONNECTION
THIS END
J17
J15
J8
5
4
6
2
1
3
J13
J4
J16
3
4
2
7
8
6
1
5
RIBBON CABLE
RIBBON CABLE
J1
J3
RED
GRN
WHT
BLK
CABLE
JUMPER SETTINGS
BLK
YEL
SELF SERVICE
ENABLE
(OPTIONAL)
DISABLE
ENABLE
EQUIPOTENTIAL
GROUND
GRN/
YEL
GRN/
YEL
GRN/
YEL
GRN/
YEL
GRN/
YEL
GRN/
YEL
BLK