Installation
4
Owner’s Responsibilities
Installation responsibilities prior to service
startup inspection
You are entitled to a free start-up inspection ser-
vice by our factory ASAP. Before a factory repre-
sentative arrives to perform a startup procedure,
the owner must already have satisfied the follow-
ing requirements.
1. Oven(s) are uncrated, stacked (if applies) and
put in place.
NOTE: Please refer to Leg Attach ment and
Stacking.
Maximum shelf loading -- 100 lbs (45.5 Kg)
RATINGS -- GAS APPLIANCES -- CNV14G/AA
Gas Type Gas Input Voltage Phase Amps Motor
U.S. and Canadian Installations
Natural 65,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
120 1 15 1/2HP 208-240VAC, 50/60 Hz
Propane 65,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
120 1 15 1/2HP 208-240VAC, 50/60 Hz
3/4” FNPT connector for all U.S. and Canadian installations
RATINGS -- ELECTRIC APPLIANCES -- CNV14E/AA
Voltage Hz Phase
Max Load (amps)
Motor
L1 L2 L3
208 60 1 89 89 --- 1/2HP 208-240VAC, 50/60 Hz
208 60 3 52 52 52 1/2HP 208-240VAC, 50/60 Hz
240 60 1 82 82 --- 1/2HP 208-240VAC, 50/60 Hz
240 60 3 47 47 47 1/2HP 208-240VAC, 50/60 Hz
480 60 3 23 23 23 1/2HP 208-240VAC, 50/60 Hz
380/220 50 3 25 25 25 1/2HP 208-240VAC, 50/60 Hz
415/240 50 3 27 27 27 1/2HP 208-240VAC, 50/60 Hz
400/230 50 3 26 26 26 1/2HP 208-240VAC, 50/60 Hz