– 41 –
Cooling Fan
The cooling fan is located in a recess in the back of
the oven. It is necessary to remove the oven from
the installation to access the cooling fan.
The fan will begin to operate when the oven is in
any cooking mode. The fan may continue to operate
even after the oven is turned off.
To remove the cooling fan:
Remove the main rear access panel. (See 1.
Rear
Access Panels.)
Disconnect the wire harness and the ground 2.
wire from the cooling fan.
Carefully grasp the assembly and tilt the unit 4.
back, up, and out of the oven frame.
Cooling Fan
Disconnect
3. Remove the four 1/4-in. hex-head screws (2
on each side) that hold the cooling fan to the
control compartment.
Disconnect
Ribbon Cable Assembly
To remove the ribbon cable assembly:
Open or remove the lower door.1.
Release the ribbon cable assembly from the 2.
door. (See
Door Assemblies.)
Remove the secondary rear access panel. (See 3.
Rear Access Panels.)
Disconnect the back of the ribbon cable from 4.
the mating connector.
Disconnect
5. Remove the 4 screws and nuts from the front
end of the ribbon cable housing.
6. Remove the ribbon cable by sliding it out of the
ribbon cable sleeve.
Note: When installing the new ribbon cable, ensure
that the new cable is positioned between the wings
of the ribbon guide located between the oven
cavities.