Smoke Eliminators
To remove the upper oven smoke eliminator:
Remove both rear access panels. (See 1. Rear
Access Panels
.)
Remove the top access panels. (See 2. Top Access
Panels
.)
Remove both left side access panels. (See 3. Side
Access Panels.)
Note: To access the vent tube, it may be necessary
to cut and fold the insulation away from the top of
the oven liner.
Remove the two 1/4-in. hex-head screws that 4.
secure the vent tube to the top of the oven liner.
Note: Upon reassembly, ensure the displaced
insulation around the oven and components is
returned to its original position.
5. Pull the vent tube straight up and out of the
oven.
6. Pry the smoke eliminator from the top of the
oven liner.
Smoke Eliminator
Vent Tube
Note: To access the lower oven smoke eliminator,
the two ovens must be separated. To separate the
upper and lower ovens, it is necessary to remove
all 4 side access panels and remove the 2 metal
brackets (1 on each side) at the front of the unit
that secure the two ovens together. Wiring that
connects the 2 ovens together must be marked and
disconnected.