Henny Penny OG-30X Fryer User Manual


 
When installing the gas fry station do not attach an exten-
sion to the gas flue exhaust stack. This may impair proper
operation of the burner, causing malfunctions and possible
negative back draft.
The gas fry station is factory available for either natural
or propane gas. Check the data plate inside the front door
of the cabinet to determine the proper gas supply
requirements.
TE
The OG-301 can be operated at altitudes of up to 4000 feet
above sea level with no changes to the unit. For operation
above 4000 feet, please contact Henny Penny Corporation
for changes to the unit.
Do not attempt to use any gas other than that specified on
the data plate. Incorrect gas supply could result in a fire
or explosion.
Please refer to the illustration on the following page for the
recommended hookup of the fry station to the main gas line
supply.
To avoid possible serious personal injury:
* Installation must conform with American National Standard
2223. l-Latest Edition National Fuel Gas Code and the local
municipal building codes. In Canada, installation must be in
accordance with Standard CAN/CGA B 1 49.1 & .2,
Installation Codes - Gas Burning Appliances and local
codes.
0 The fry station and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
l/2 PSIG (3.45 KPA).
* The fry station must be isolated from the gas supply piping
system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping system
at test pressures equal to or less than l/2 PSIG (3.45 KPA).