Henny Penny OG-30X Fryer User Manual


 
tep 2
4. Remove the 90° connector and conduit from the old gas
valve and install on the replacement gas valve.
5. Remove the four screws securing the operator and gasket.
6. Secure the new operator and gasket with the four screws
provided.
7. Reconnect the gas valve wires.
8. Install the control panel per paragraph 5-4.
Check Procedure
120 volt - 50/60 Hz - 235-ohms
208-240 volt - 50/60 Hz - 880-ohms
1. Remove the two screws securing regulator to the operator.
2. Replace with the new gasket and regulator and secure with
the two screws supplied.
1. Remove by unscrewing the hexagon shaped plug, with a
5/8 inch socket wrench.
2. Install the new magnetic plug by applying a small amount
of thread lubricant and tighten the plug to prevent a gas
leak.