Gas model fryers are factory available for either NATURAL
GAS or PROPANE GAS. Factory conversion kits for natural
gas and propane gas are available that require the burner jets,
pilot jet and regulator assembly to be changed.
Conversion must be accomplished by an authorized
Henny Penny dealer or service representative, or per-
sonal injury could result.
On NATURAL GAS installation, the gas pressure regulator
on the automatic gas control valve is factory set at 3.5 inch
water column.
On PROPANE GAS installations, the gas pressure regulator
on the automatic gas control valve is factory set at 10.0 inch
water column.
After converting the fryer, turn on the gas supply and check
for leaks. A simple method is to brush all the connections with
soapy water, and watch for bubbles which indicate escaping
gas.
Never use an open flame to test for leaks. Escaping
gas could cause an explosion, and personal injury or
property damage could result.