Henny Penny OG-30X Fryer User Manual


 
Depress lightly and turn manual lever on gas valve to
the OFF position.
The gas pressure regulator on the automatic gas valve is
factory set as follows:
@ Natural: 3.5 inches water column.
* Propane 10 0 inches water column.
e
120 V, 50/60 Hz., 12 A, 1 PH
0 230 V, 50/60 HZ., 6 A, 1 PH
The gas fry station requires a 3 wire grounded service.
I
W
ING
c
DO NOT DISCONNECT THE GROUND PLUG. This
fry station MUST be adequately and safely grounded or
electrical shock could result. Refer to local electrical
codes for correct grounding procedures or in absence of
local codes, with the National Electrical Code,
ANSO/NFPA No. 70 Latest Edition. Canadian models
are supplied with a terminal box, suitable for conduit
connection. In Canada, all electrical connections are to
be made in accordance with CSA C22 1, Canadian
Electrical Code Part 1, and/or local codes.
Servicing of the filter pump is done at the rear of the
unit. If service is required, disconnect the fry station
from the electrical power source. The fry station will
have to be pulled out from the wall.to gain access to
rear.