Henny Penny OG-30X Fryer User Manual


 
Disconnect power supplied to the unit by unplugging the power
cord, or turning off the wall circuit breaker, or fuse. Be aware
that the other controls will HAVE power on electric models,
or electrical shock could result.
2. Swing control panel down per section 6-3.
3. Inspect the probe connection at the board, making sure of
a good connection.
4. Replace control panel, reconnect power supply and turn
power switch to on position. If E6 persists continue on to
step 5.
5. Disconnect power to unit and remove control panel per sec-
tion 6-3.
6. Drain the shortening from cookpot (electric units continue
to step 8).
7. Remove heat shield from unit.
8. Using a l/2” wrench, loosen nut on compression fitting and
pull probe from pot fitting.
9. Install new probe, making sure the probe extends out to
the outer diameter of the heating elements on electric units.
On gas units, the probe should extend to the outer edge
of probe guard, making sure it doesn’t extend out past
guard.
Care must be taken not to extend the probe beyond the points
described above, or damage to the probe could result. Also,
make sure locking ferrule is in place and do not over-tighten
nut or damage to probe could result. Snug nut up and tighten
l/4 turn past this point.