Henny Penny OG-30X Fryer User Manual


 
Shortening will
not heat, but
lights are on.
A. Pilot will not
light (gas model)
B. Pilot will not
stay lit.
C. Burner will
not light, pilot li
(gas model)
Faulty Contactor
(elec. model)
Faulty Thermal
Sensor
Faulty High
Limit
Pilot not lit
Plugged pilot
orifice, and/or
pilot supply tube
Gas supply off
Faulty gas con-
trol valve
Air in gas supply
line
Faulty therm0
couple
Pilot magnetic
PlW
Drain valve open
High Limit con-
trol switch open
Possible faulty
gas control valve
Check contactor per Section 6-8.
Check thermal sensor per Section 6-4. “Error message” E6.
Check high limit control switch per Section 6-6 or 6-7.
* Light pilot per Section 2-9.
* Unplug pilot orifice and/or pilot supply tube.
Turn ON gas supply.
Replace gas control valve.
Bleed air from supply line.
Replace therm0 couple per Section 6-10.
Service per Section 6-11.
Close drain valve.
With power removed from fryer, check across high limit
switch terminals with ohmmeter. Replace if no reading is
indicated on meter.
With power removed from fryer, check across electrical
leads of gas control valve with ohmmeter, and gas valve in
“ON” position. Ohm reading should be 234 ohm resistance.
Replace the control valve if not within 10%.