The filter pump motor is equipped with a manual reset but-
ton in the event the motor’s thermal protector acuates. This
reset button is located on the rear of the motor. Wait ap-
proximately 5 minutes before attempting to reset this pro-
tector device.
To prevent burns caused by splashing shortening, the unit’s
filter pump switch must be in the OFF position before reset-
ting the filter pump motor’s manual reset protector device.
The reset button will take some effort to reset. A
screwdriver could be used to press against the reset button
to aid in resetting the protector device.
The filter envelope should be changed after lo-12 filterings
or whenever it becomes clogged with crumbs. Proceed as
follows:
1. Move the main power switch to the OFF position.
2. Disconnect the filter union and-remove the filter drain
pan from beneath the cookpot.
This union may be hot. Use protective gloves or clothes to
prevent burns. Also use care to prevent burns caused by
splashing of hot shortening.
3. Remove drain pan cover from drain pan and lift the
screen assembly from the drain pan.
4. Wipe the shortening and crumbs from the drain pan.
Clean the drain pan with soap and water. Thoroughly
rinse with hot water.
5. Unthread the suction standpipe from the screen
assembly.
6. Remove the crumb catcher and clean thoroughly with
soap and water. Rinse thoroughly with hot water.
7. Remove the filter clips and discard the filter envelope.