Henny Penny OG-30X Fryer User Manual


 
6-9. ASS
)
1. Remove the control panel per section 6-3.
2. Open doors to bottom of unit.
3. Remove the flexible conduit from the heat shield and
shroud which contains the wires of the gas valve and
solenoid.
4. Disconnect gas supply line from connector at gas valve.
t
5. Loosen the two screws on the Heat Shield Deflector on
the firebox and flue assembly and raise deflector to its
highest position. Retighten screws to hold at this position.
6. Remove U-bolt from bracket.
7. Remove and label wires from terminal block behind panel.
8. Remove two screws from gas valve heat shield.
9. Remove entire gas burner assembly, by lifting and pull-
ing toward front of fryer.
a. Replace thermocouple as required per section 6-10.
b. Repair or replace gas valve as required per section 6-11.
c. Replace orifices as required.
There are 23 brass and 1 stainless steel orifice. The stainless
steel orifice is to be mounted adjacent to the pilot light.
10. Make other repairs or replacements as required.
11. Install entire gas burner assembly, reverse of above steps.
12.‘r‘urn on the gas supply to that frypot.
Check for leaks per section 2-7. Leaking gas may cause an
explosion.
13. Connect the power cord to the wall receptacle.
14. Relight the gas pilot per the instructions in section 2-9.