Henny Penny OG-30X Fryer User Manual


 
ode
The electric fryers have two 15 amp fuses to protect the cir-
cuitry, and two 15 amp fuse to protect the PC board, for each
control panel, found behind doors, up under shroud. The gas
units do not have fuses other than at the main power source.
Each PC board has a 1.5 amp fuse as a surge protec-
tor. If the power comes on, but no display, check this
fuse.
Before starting this procedure, move the power switch
to the OFF position and unplug the power cord at the
wall receptacle, for the panel to be worked on. Be aware
the other controls will have power, or electrical shock
could result.
1. Remove control panel per section 6-3.
2. Remove wires to fuse holders.
3. Using a continuity light, or volt meter, the circuit should
be closed across terminals. If open, replace fuse.