Henny Penny OG-30X Fryer User Manual


 
odel
Foaming or boil-
ing over of
shortening.
Shortening will
Drain valve
not drain from clogged with
frypot crumbs
Filter motor rum
but pumps
shortening slowly
Filter switch ON
motor does not
run
.“Y Motor hums but
Lb,&> will not pump
Water in
shortening
Improper or bad
shortening
Improper
filtering
Improper rinsing
after cleaning the
fryer
Drain valve will
not open by turn-
ing handle
Filter valve not
open
Pump clogged
Filter line con-
nection loose
Solidified
shortening in
lines
Defective switch
Defective motor
Motor thermal
protector tripped
Clogged lines or
pump
At end of frying cycle, drain shortening and clean frypot.
Add fresh shortening.
Use recommended shortening.
Refer to the procedure covering filtering the shortening.
@ Clean and rinse the frypot. Then dry thoroughly.
8 Open valve force cleaning brush through drain opening.
a Replace cotler pins in in valve capling.
Open filter valve.
Remove and clean pump per Section 6-15.
Tighten all filter line connections.
Clear all filter lines of solidified shortening.
Check/replace switch per Section 6-15.
Check/replace motor per Section 6-15.
Reset thermal switch per Section 3-7.
Remove and clean pump and lines.
Replace pump seal, rotor and rollers per 6-15.
5-5